46 resultados para sensitivity and specificity

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background—Palpation is an important clinical test for jumper's knee.

Objectives—To (a) test the reproducibility of palpation tenderness, (b) evaluate the sensitivity and specificity of palpation in subjects with clinical symptoms of jumper's knee, and (c) determine whether tenderness to palpation may serve as a useful screening test for patellar tendinopathy. The yardstick for diagnosis of patellar tendinopathy was ultrasonographic abnormality.

Methods—In 326 junior symptomatic and asymptomatic athletes' tendons, palpation was performed by a single examiner before ultrasonographic examination by a certified ultrasound radiologist. In 58 tendons, palpation was performed twice to test reliability. Tenderness to palpation was scored on a scale from 0 to 3 where 0 represented no pain, and 1, 2, and 3 represented mild, moderate, and severe tenderness respectively.

Results—Patellar tendon palpation was a reliable examination for a single examiner (Pearson r = 0.82). In symptomatic tendons, the positive predictive value of palpation was 68%. As a screening examination in asymptomatic subjects, the positive predictive value of tendon palpation was 36–38%. Moderate and severe palpation tenderness were better predictors of ultrasonographic tendon pathology than absent or mild tenderness (p<0.001). Tender and symptomatic tendons were more likely to have ultrasound abnormality than tenderness alone (p<0.01).

Conclusions—In this age group, palpation is a reliable test but it is not cost effective in detecting patellar tendinopathy in a preparticipation examination. In symptomatic tendons, palpation is a moderately sensitive but not specific test. Mild tenderness in the patellar tendons in asymptomatic jumping athletes should be considered normal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:



A modified version of the popular agrohydrological model SWAP has been used to evaluate modelling of soil water flow and crop growth at field situations in which water repellency causes preferential flow. The parameter sensitivity in such situations has been studied. Three options to model soil water flow within SWAP are described and compared: uniform flow, the classical mobile-immobile concept, and a recent concept accounting for the dynamics of finger development resulting from unstable infiltration. Data collected from a severely water-repellent affected soil located in Australia were used to compare and evaluate the usefulness of the modelling options for the agricultural management of such soils.

The study shows that an assumption of uniform flow in a water-repellent soil profile leads to an underestimation of groundwater recharge and an overestimation of plant transpiration and crop production. The new concept of modelling taking finger dynamics into account provides greater flexibility and can more accurately model the observed effects of preferential flow compared with the classical mobile–immobile concept. The parameter analysis indicates that the most important factor defining the presence and extremity of preferential flow is the critical soil water content.

Comparison of the modelling results with the Australian field data showed that without the use of a preferential flow module, the effects of the clay amendments to the soil were insufficiently reproduced in the dry matter production results. This means that the physical characteristics of the soil alone are not sufficient to explain the measured increase in production on clay amended soils. However, modelling with the module accounting for finger dynamics indicated that the preferential flow in water repellent soils that had not been treated with clay caused water stress for the crops, which would explain the decrease in production.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: To assess the validity of the Child Health Questionnaire (CHQ) as a screening tool for detecting 'at risk' emotional and behavioural  maladjustment in children with diabetes, using the Behaviour Assessment System for Children (BASC) as a gold standard measure. Methods: CHQ and BASC were administered to 103 parents of children with Type 1 diabetes, aged 7–12 years. Sub-scales of the two measures were compared using Pearson's bivariate correlations. CHQ sensitivity and specificity cut-points were optimized against the BASC borderline category using receiver operating characteristic curves. Results: The BASC Externalizing Problems scale correlated strongly with CHQ Behaviour, Global Behaviour, Mental Health, Family Activities and Family Cohesion scales (r-values −0.68, −0.54, −0.51, −0.59, and −0.42, respectively). BASC Internalizing Problems scale correlated strongly with CHQ Behaviour, Mental Health and Family Cohesion scales (r-values −0.40, −0.43 and −0.45, respectively). Using receiver operating characteristic curve analysis, the CHQ Mental Health scale most effectively identified children classified as borderline on the BASC Internalizing Problems scale (sensitivity 87%, specificity 78%), while the CHQ Global Behaviour scale most effectively identified children classified as borderline on the BASC Externalizing Problems scale (sensitivity 73%, specificity 82%). Conclusions: Significant correlations were seen between the CHQ Global Behaviour and Mental Health scales and the BASC Externalizing and Internalizing scales, respectively. Sequential use of the CHQ, as a screening tool, followed by an established mental health measure such as the BASC, may help identify children with diabetes 'at risk' for chronic maladjustment and poor health outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To investigate prospectively the relative accuracy of computed tomographic (CT) angiography, calcium scoring (CS), and both methods combined in demonstrating coronary artery stenoses by using conventional angiography as the reference standard. MATERIALS AND METHODS: The study was approved by the institutional review board Human Research Ethics Committee, and all patients completed written informed consent. Fifty patients (40 men, 10 women) aged 62 years ± 11 (± standard deviation) who were suspected of having coronary artery disease underwent both conventional coronary angiography and multisection coronary CT angiography with CS. Sensitivity and specificity of CS, CT angiography, and both methods combined in demonstrating luminal stenosis greater than or equal to 50% were determined for each arterial segment, coronary vessel, and patient. Receiver operating characteristic (ROC) curves were generated for CS prediction of significant stenosis, and the Mann-Whitney U test was used for comparison of CS between groups. RESULTS: When used with segment-specific electrocardiographic phase reconstructions, CT angiography demonstrated stenosed segments with 79% sensitivity and 95% specificity. Mean calcium score was greater in segments, vessels, and patients with stenoses than in segments, vessels, and patients without stenoses (P < .001 for all); nine (16%) of 56 stenosed segments, however, had a calcium score of 0. The patient calcium score correlated strongly with the number of stenosed arteries (Spearman {rho} = 0.75, P < .001). CS was more accurate in demonstrating stenosis in patients than in segments (areas under ROC curve were 0.88 and 0.74, respectively). CT angiography, however, was more accurate than CS in demonstrating stenosis in patients, vessels, and segments. The sensitivity and specificity of CS varied according to the threshold used, but when the calcium score cutoff (ie, >150) matched the specificity of CT angiography (95%), the sensitivity of CS in demonstrating stenosed segments was 29% (compared with 79% for CT angiography). Combining CT angiography with CS (at threshold of 400) improved the sensitivity of CT angiography (from 93% to 100%) in demonstrating significant coronary disease in patients, without a loss of specificity (85%); this finding, however, was not statistically significant. CONCLUSION: CT angiography is more accurate than CS in demonstrating coronary stenoses. A patient calcium score of greater than or equal to 400, however, can be used to potentially identify patients with significant coronary stenoses not detected at CT angiography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current study was conducted to investigate the relationships between body size estimations and disordered eating symptomatology. The method of constant stimuli was used to derive three measures of self-perceived body size in 93 women: (1) accuracy of body size estimations (body image distortion); (2) sensitivity in discriminating body size within blocks of trials (body image sensitivity); and (3) variability in making body size estimations between blocks of trials (body image variability). Participants also completed measures of disordered eating. Although body image distortion correlated with dietary restraint and eating concern, body image variability accounted for additional variance in these variables, as well as variance in binge eating. The relationships involving body image variability were found to be mediated by body dissatisfaction and internalization of the thin ideal. Together, these results are consistent with the proposition that body image variability is a significant factor in disordered eating.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Objective: To describe the diagnostic accuracy and practical application of the Peter James Centre Falls Risk Assessment Tool (PJC-FRAT), a multidisciplinary falls risk screening and intervention deployment instrument.

Methods: In phase 1, the accuracy of the PJC-FRAT was prospectively compared to a gold standard (the STRATIFY) on a cohort of subacute hospital patients (n = 122). In phase 2, the PJC-FRAT was temporally reassessed using a subsequent cohort (n = 316), with results compared to those of phase 1. Primary outcomes were falls (events), fallers (patients who fell), and hospital completion rates of the PJC-FRAT.

Results: In phase 1, PJC-FRAT accuracy of identifying fallers showed  sensitivity of 73% (bootstrap 95% confidence interval CI = 55, 90) and specificity of 75% (95% CI = 66, 83), compared with the STRATIFY (cutoff ≥ 2/5) sensitivity of 77% (95% CI = 59, 92) and specificity of 51% (95% CI = 41, 61). This difference was not significant. In phase 2, accuracy of nursing staff using the PJC-FRAT was lower. PJC-FRAT completion rates varied among disciplines over both phases: nurses and physiotherapists, ≥90%; occupational therapists, ≥82%; and medical officers, ≥57%.

Conclusion:
The PJC-FRAT was practical and relatively accurate as a predictor of falls and a deployment instrument for falls prevention interventions, although continued staff education may be necessary to maintain its accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Currently, diagnostic tests for mesenteric ischaemia and infarction are inadequate due to poor sensitivity and specificity. In addition, many potential markers appear too late to be clinically useful. At present, definitive diagnosis can only be made at the time of surgery, which is not ideal as surgery is often to be avoided in critically ill and elderly patients. A clinically useful, minimally invasive test is likely to decrease the currently very high mortality rate and allow monitoring of 'at risk' patients during their hospital stay. A two-dimensional electrophoresis based proteomic approach was undertaken to assess plasma protein differences between patients with surgically confirmed bowel infarction and control Intensive Care patients. The major protein differences were found to be members or variants of acute phase proteins. Serum amyloid A showed the largest difference between the two patient groups, and this protein was investigated in greater depth. An analysis was performed to compare the diagnostic ability of several commonly used indicators of critical illness and bowel infarction with serum amyloid A and phospholipase A2. Although none of the variables were ideal for clinical use, plasma phospholipase A2 activity showed the best discriminatory power, as determined by Receiver Operating Characteristic curves. From a review of the literature, phospholipase AI (PLA2) appeared to be increased in the bowel as a result of ischaemia and infarction. In one patient, matched tissues were obtained, and PLA2 activity was found to be significantly higher in infarcted bowel tissue compared to ischaemic bowel tissue. PLA2 activity was significantly greater in bowel lumen than tissue, suggesting that the protein was being released, and may enter the circulation. PLA2 activity was increased in the plasma of bowel infarction patients compared with control patients, though the difference was not significant. The phospholipase activity exhibited a number of similarities to typical phospholipase A2 proteins, but also showed a number of inconsistent characteristics. For this reason, we wished to identify the protein responsible for the increased phospholipase activity in infarcted human bowel. The PLA2 activity in human bowel could not be abolished by immunoprecipitation of the PLA2 isoforms IIA (well described in bowel) and V (a closely related isoform). To investigate these proteins, a native urea protein gel devised for snake venom phospholipase A2 was modified for use with mammalian phospholipase AI. The modified gel was used to show that the protein with phospholipase activity from infarcted gut was different from normal gut PLA2 and type IIA PLA2. A number of extensions were devised for these native gels and were found to be useful both in this investigation and for venom investigations. Protein purification was undertaken to identify the protein responsible for the increased phospholipase activity in infarcted bowel. Protein was purified from infarcted human bowel using a number of techniques that exploited unusual characteristics of the protein. The purification techniques each retained the native activity of the protein and the purification could therefore be monitored with a phospholipid hydrolysis assay at each stage. The protein identified by mass spectrometry was an excellent match for cyclophilin B, an inflammatory protein that had previously been identified in rat bowel at the mRNA level (Hasel et al, 1991, Kainer & Doris, 2000). As the purification progress had been monitored throughout with a phospholipid hydrolysis assay, cyclophilin B was an unexpected identification, as it is not known to have phospholipase activity. Cyclophilin B was removed from the highly purified samples via immunoprecipitation and this process abolished all phospholipase activity. The addition of cyclosporin A, (the pharmaceutical ligand of cyclophilin B), did not effect the phospholipase activity. Cyclophilin B protein was found in normal and infarcted human bowel using Western blotting. Cyclophilin B protein also appeared to be present in the bowel lumen and plasma of several patients with bowel infarction, but not in control patients. Immunohistochemistry confirmed the ubiquitous nature of cyclophilin B that had been reported by other groups. This project has investigated the use of two dimensional gel electrophoresis based proteomics to identify proteins present in the plasma of patients with confirmed bowel infarction and control intensive care patients. The major protein classes observed were members of the acute phase proteins, which highlights the need for pre-fractionation of plasma to identify lower abundance, disease associated proteins. A series of potential plasma markers were compared using Receiver Operating Characteristic Curves. Although no ideal marker was clear from this analysis, phospholipase activity appeared to warrant further investigation. Phospholipase activity was investigated in human infarcted bowel. Protein purification identified cyclophilin B as a bowel protein that showed unusual phospholipid hydrolysing activity. Cyclophilin B is a ubiquitous protein in intestinal cell types in both normal and infarcted tissue. There appears to be release of cyclophilin B into bowel lumen and plasma under conditions of mesenteric ischaemia and infarction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to test whether calculated inclusion of cultural sensitivity in a selected entrepreneurial business planning (EBP) process could increase sales growth in a test market and to explore the implications of a positive answer for the theory and practice of entrepreneurial business planning. Execution of a pretest-posttest control group experimental design measured and compared the implemented effectiveness of a planned entrepreneurial initiative based on cultural sensitivity. Though small in scale and limited in focus, the initiative qualified as an example of entrepreneurial business planning (EBP) and could be used to apply, test and extend aspects of the developing theory in this field of entrepreneurship research. Since the initiative was planned to overcome a culturally-defined impediment to business growth, it also offered opportunity to explore the specific importance of cultural variables in the context of EBP.

A planned sales-promotion was offered to a control group (receiving information in English) and a treatment group (who received the information in the language of ethnic origin). The sixty subjects had been chosen at random from a population of route-trade retailers of defined ethnic origins (Greek, Lebanese and Chinese) and randomly assigned to control and treatment groups. Monthly sales averages of the promoted product were measured before and after treatment. A Chi Square test was used to evaluate the relative proportion of the control and treatment groups who accepted the promotional offer. A two sample t-test procedure and complementary non-parametric Mann-Whitney test were performed to compare the mean sales-performance change of the two groups. Analysis showed that there was a significant increase in mean sales when the planned entrepreneurial initiative was communicated in the relevant language of origin.

The experimental results have specific practical relevance to revitalising the deteriorating route-trade segment of the Australian confectionery market through increasing the sales growth of wholesalers who are prepared to act entrepreneurially and include cultural sensitivity as an element in planning and implementation. By introducing cultural sensitivity as a necessary extension of a plan’s communications role, the results also have general theoretical implications for the developing paradigm of entrepreneurial business planning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background
Accelerometers have been used to determine the amount of time that children spend sedentary. However, as time spent sitting may be detrimental to health, research is needed to examine whether accelerometer sedentary cut-points reflect the amount of time children spend sitting. The aim of this study was to: a) examine agreement between ActiGraph (AG) cut-points for sedentary time and objectively-assessed periods of free-living sitting and sitting plus standing time using the activPAL (aP); and b) identify cut-points to determine time spent sitting and sitting plus standing.

Methods
Forty-eight children (54% boys) aged 8–12 years wore a waist-mounted AG and thigh-mounted aP for two consecutive school days (9–3:30 pm). AG data were analyzed using 17 cut-points between 50–850 counts·min−1 in 50 counts·min−1 increments to determine sedentary time during class-time, break time and school hours. Sitting and sitting plus standing time were obtained from the aP for these periods. Limits of agreement were computed to evaluate bias between AG50 to AG850 sedentary time and sitting and sitting plus standing time. Receiver Operator Characteristic (ROC) analyses identified AG cutpoints that maximized sensitivity and specificity for sitting and sitting plus standing time.

Results
The smallest mean bias between aP sitting time and AG sedentary time was AG150 for class time (3.8 minutes), AG50 for break time (−0.8 minutes), and AG100 for school hours (−5.2 minutes). For sitting plus standing time, the smallest bias was observed for AG850. ROC analyses revealed an optimal cut-point of 96 counts·min−1 (AUC = 0.75) for sitting time, which had acceptable sensitivity (71.7%) and specificity (67.8%). No optimal cut-point was obtained for sitting plus standing (AUC = 0.51).

Conclusions
Estimates of free-living sitting time in children during school hours can be obtained using an AG cut-point of 100 counts·min−1. Higher sedentary cut-points may capture both sitting and standing time.